I.System Description
Biological (cells, mitochondria, etc.)
measurement of oxygen characteristics of computer analysis system, the
project the Department of Chinese People's Liberation Army 304 Hospital
and the joint development.
II.System structure and working principle
1. Blood pressure
According to physics, to a certain temperature conditions, the gas solubility
in liquids, in a certain range it is proportional to the partial pressure,
that is, the higher its partial pressure, was dissolved more the less
the other hand, it blood oxygen content of different machines, the partial
pressure of oxygen is different, high blood pressure, blood oxygen content,
and low blood pressure, blood oxygen content of less, it directly reflects
the blood partial pressure of oxygen in blood how much oxygen.
Clinical detection of blood oxygen partial pressure of the methods,
namely, arterial blood samples for blood gas analysis, and the other
is non-invasive transcutaneous measurement of blood pressure.
2. Oxygen saturation
Red blood cells in the blood plays a role of oxygen and hemoglobin to
be completed by. Hemoglobin molecule in hemoglobin with four oxygen
binding in the standard mode, if the hemoglobin with oxygen exposure,
when reaching saturation, the per gram of hemoglobin can be combined
with 1. 34mL oxygen when the oxygen saturation of hemoglobin of 100
%, while in fact most of oxygen saturation in non-saturation, normal
for 95-98%. Oxygen saturation of blood oxygen saturation can be used
to measure equipment.
Oxygen saturation of hemoglobin is only a reflection of the extent of
combining with oxygen, can only indirectly reflect the amount of oxygen,
rather than the direct representative of blood oxygen content.
3. Blood pressure and oxygen saturation relations
Between the two is not equivalent to, but the relationship between a
fixed, usually referred to as "S" curve, that is, oxyhemoglobin
dissociation curve. Under normal circumstances, when the partial pressure
of oxygen to 100mmHg, the corresponding oxygen saturation was 98%, partial
pressure of oxygen fell to 60mmHg, the oxygen saturation dropped to
90%, that is, a decrease of oxygen partial pressure 40mmHg, oxygen saturation
decreased by only 8%, only when the partial pressure of oxygen less
than 40mmHg, the oxygen saturation will decrease rapidly. It is only
based on oxygen saturation to determine the hypoxic conditions, while
the body is often neglected early hypoxia, was to conceal, easy to delayed
diagnosis or failure to give timely treatment.
4. Under conditions of high oxygen partial pressure monitoring
When atmospheric oxygen or liquid oxygen at the high-drip, blood pressure
often is greater than 100mmHg, blood oxygen saturation reached saturation
levels, that is 100%, partial pressure of oxygen and then how changes
in oxygen saturation is not reflected by the instrument , and transcutaneous
oxygen pressure measurement can fully demonstrate its clinical value.
Instructions:
1. Function: Characteristics of biological materials is the evaluation
of oxygen vitality and function of organisms an important indicator,
so in biology, low temperature biology, physiology, pathology, genetics,
clinical medicine, pharmacology, nutrition and other fields, how to
its measurement and analysis, has attracted much public concern and
the need to resolve an important issue.
Mitochondria is an important cellular organelle is the place for cell
respiration, cell energy needs of the various activities, mainly through
the mitochondrial respiration to provide. Studies have shown that mitochondrial
ATP synthesis in addition to, but also extremely important with a wide
range of cell functions, including generation of reactive oxygen species
superoxide anion, redox regulation of cell redox potential and conduction,
regulation of apoptosis and gene expression and growth in biological
, development, aging, disease, death, and the study of biological evolution,
there are important theoretical and practical significance, and thus
the current life sciences constitute a new growth point.
"Measurement of biological oxygen characteristics of computer analysis
system," the organization may be tablets, organizations at the
end of tissue, cells, mitochondria and other characteristics of wood
samples to measure oxygen and analytical processing, which can be obtained
within a certain period of time the oxygen consumption, oxygen consumption
change rate, the efficiency of oxidative phosphorylation, respiratory
control ratio, and results.
2. Composition: mainly by the electromagnetic stirrer system, measurement
of oxygen tanks, oxygen electrode, the system-specific circuit, constant
temperature heating circuits, micro-computers, printers, system-specific
software, etc..
3 . Characteristics: the system of Biophysics, Chinese Academy of Sciences,
the military medical, the medical department of Peking University, Shanghai
Second Medical University, Third Military Medical University, Shandong
College of Life Sciences, O People's Liberation Army Hospital three
years of application and other units, we can see the system has the
following salient features:
Test items and more powerful; micro-computer automatic data collection,
rapid analysis, and the results stored; compared with manual processing,
greatly improving the speed and accuracy of the calculation; to graphic
files (the original test curve) and text files ( original data) the
form of a large number of experimental data and results stored for at
any time to find, retrieve or print output; computer interface clarity
can be flexible for a variety of experimental projects and select and
set parameters; simple; oxygen electrode design, high sensitivity, dark
current small, durable; cost-effective than foreign products.
4 . Principle: Polarographic oxygen electrode is based on principle
and made, it is a unique electrochemical gas sensing device, the cathode
and anode voltage of the role of a certain polarization, the gas permeable
membrane and through the spread of oxygen within the electrolyte resulting
electrochemical reaction, the reaction produced a very weak current
and the partial pressure of oxygen outside the membrane is proportional
to, the weak signal amplification, processing, transformation evacuation
analysis of micro-computer processing and computing, data and results
into the hard disk. Heating and temperature measuring circuit so that
the liquid oxygen tank temperature, electromagnetic stirrer can reduce
the pool of liquid temperature gradient.
III.Biological oxygen measurement data
analysis software
This software includes the organization
of film on the oxygen consumption, organize beads and homogenized, cells,
mitochondria, such as the four test items, including data collection,
analysis, calculation, if necessary, to graphics or data should be archived,
the experiment 23 kinds of tests may also media, sampling period, sampling
time, dissolution coefficient, medium size, partial pressure of oxygen
values, organization, and the weight of set temperature, ADP value selection
or settings. Sampling period can be set, but the sampling time for tens
of seconds, the sampling period can be set at 100 ms, sampling time
of up to hundreds of seconds, the sampling period may be set for 1000
ms, so in 1000 to ensure that sampling points around a reasonable number
of sampling points have data redundancy, sampling points less information
will be lost. Dissolution coefficient, medium size, partial pressure
of oxygen values, body weight, temperature, ADP values can be modified
at any time, together with the unit automatically. Set temperature for
the system upgrade to prepare for the future, the system temperature
can be measured and fed back to the front-end control system in order
to specify the temperature constant. Real-time data window can display
the current value of the temperature and oxygen partial pressure, or
their relative value. The mouse position of the window can display the
current mouse coordinates, such as the status of data analysis in the
former data will be turned into a window, change the meaning of Department
data showed that the mouse the corresponding point of time and oxygen
partial pressure value. Choice of paper can turn a good collection of
data files or a new key file, new documents can be by date, the day
the number of experiments and test projects, such as auto-naming can
also be specified further.
The relevant parameters and, following
the specified file name, you can start by sampling of sampling, at the
same time will automatically record the current settings as the default
value of the next sample. Analysis for different test items have different
data processing methods and the corresponding formula, please refer
to user manual. Graphics output is to curve analysis and calculation
results using a standard BMP file format disk, so that such procedures
can be dealt with brush and through the printer to print out.
Analysis of the text output is to be
calculated and collected data to standard file formats WRI disk so that
you can write procedures, etc. and print them out through the printer.
* Equipment warranty for one year,
long-term technical services
* Computer, printer-matching